Echocardiographic Diagnostics of Myocardial Infarction in Newborns

https://doi.org/10.15690/pf.v12i3.1358

Abstract

Early and correct diagnostics of myocardial infarction in newborns is impossible without modern instrumental methods, among which echocardiography is the leading one. Hypokinesia, akinesia or dyskinesia of local segments of the heart ventricular wall is determined with echocardiography. We examined a 3-days-old baby with circulatory failure requiring cardiotonic support. On auscultation there was a heart murmur. It was an intracardiac conduction disoder and infarction-like changes on ECG, however, a convincing evidence to interpret the patient’s condition as myocardial infarction has not been received. Therefore, it was decided to conduct echocardiography. According to the results of echocardiography the presence of hyperechogenic diskinetic locus in the apical segment of the right ventricle (post-infarction scar), a local pericardial effusion in the same projection, hyperechogenic movable mass (thrombus) in the apical segment of the right ventricle were determined that together with the results of the ECG allowed us to set diagnosis myocardial infarction. Transthoracic echocardiography is one of highly informative methods; the data obtained allowed to correctly interpret the clinical picture of heart failure and to reveal the cause of the patien’st dependance on cardiotonic support.

About the Authors

G. V. Revunenkov
Scientific Center of Children’s Health
Russian Federation
Moscow


K. A. Valyalov
Scientific Center of Children’s Health
Russian Federation
Moscow


References

1. Гребенников В. А., Миленин О. Б., Рюмина Н. И. Респира торный дистресс-синдром у нововрожденных. М. 1995. С. 55–56.

2. Царегородцева Л. В., Прахов А. В. Диагностика инфаркта миокарда у детей. Лечащий врач. 2004; 2: 60–64.

3. Гуревич П. С., Ковалёва Л. С., Желябкин А. В. и др. Вопросы охраны материнства и детства. 1986; 12: 47–50.

4. Добронравов А. В., Добронравов В. А. Вопросы охраны материнства и детства. 1986; 2: 24–27.

5. Моисеев Д. Б., Подкопаев В. Н., Ватолин К. П., Пыков М. И., Тара сова А. А., Кузовкова Г. И., Сизов С. В., Маркова Л. А. Проблемы диагностики инфаркта миокарда у новорожденных после острой интранатальной асфиксии тяжелой степени с развитием тяжелой степени поражения ЦНС. Анестезия и реаниматология. 1998; 1: 64–67.

6. Farooqi K. M., Sutton N., Weinstein S., Menegus M., SpindolaFranco H., Pass R. H. Neonatal myocardial infarction: case report and review of the literature. Congenit Heart Dis. 2012 Nov-Dec; 7 (6): E97–102. [Medline].

7. Poonai N., Kornecki A., Buffo I., Pepelassis D. Neonatal myocardial infarction secondary to umbilical venous catheterization: A case report and review of the literature. Paediatr Child Health. 2009 Oct; 14 (8): 539–41. [Medline].


Review

For citations:


Revunenkov G.V., Valyalov K.A. Echocardiographic Diagnostics of Myocardial Infarction in Newborns. Pediatric pharmacology. 2015;12(3):320-322. https://doi.org/10.15690/pf.v12i3.1358

Views: 855


ISSN 1727-5776 (Print)
ISSN 2500-3089 (Online)